Effect Of Storage Time And Temperature On Platelet Indices Of EDTA Samples
Effect of storage on platelet indices
DOI:
https://doi.org/10.54393/pbmj.v4i2.80Abstract
This study was conducted to find effect of storage time and temperature on platelet indices of samples taken in EDTA. Methods:In this study 100 samples without the specification of gender were included. CBC samples were taken in two EDTA vials from each patient. All the samples were separated in two groups. One sample group was stored at room temperature(RT) and other at 2-6°C. CBC was run on CBC analyzer Sysmex XN-1000 at 0 hours, 4 hours, 12 hours and 24 hours. Results: There was significantly increasing trend for MPV, PDW and P-LCRat RT and decreasing trend at 4°C when compared with 0 hours. PCT showed significant decreasing trend at 4°C with respect to 0 hours. Significant decrease in platelet count was observed after storage at room temperature as well as at 4°C. Conclusion:Although 4°C consider as optimal temperature to transport specimen for CBC but Platelet Indices values varies significantly in comparison to baseline when stored at 4oC and at room temperature. It seems prudent to conclude that if platelet pathology is the major drive for CBC test performance then specimen should be run without delay.
References
Holinstat M. Normal platelet function. Cancer Metastasis Rev. (2017) 36(2):195-8. doi: 10.1007/s10555-017-9677-x
https://doi.org/10.1007/s10555-017-9677-x
Budak YU, Polat M, Huysal K. The use of platelet indices, plateletcrit, mean platelet volume and platelet distribution width in emergency non-traumatic abdominal surgery: a systematic review. Biochemia Medica. (2016) 26(2):178-93. doi: 10.11613/BM.2016.020
https://doi.org/10.11613/BM.2016.020
Zhang S, Cui Y-L, Diao M-Y, Chen D-C, Lin Z. F. Use of platelet indices for determining illness severity and predicting prognosis in critically ill patients. Chinese med. j. (2015) 128(15):2012. doi: 10.4103/0366-6999.161346.
https://doi.org/10.4103/0366-6999.161346
Budak YU, Polat M, Huysal K. The use of platelet indices, plateletcrit, mean platelet volume and platelet distribution width in emergency non-traumatic abdominal surgery: a systematic review. Biochemia medica: (2016) 26(2):178-93. doi: 10.11613/BM.2016.020
https://doi.org/10.11613/BM.2016.020
Vinholt PJ, Hvas AM, Nybo M. An overview of platelet indices and methods for evaluating platelet function in thrombocytopenic patients. Eu. J. haema. (2014) 92(5):367-76. doi: 10.1111/ejh.12262
https://doi.org/10.1111/ejh.12262
Chu SG, Becker RC, Berger PB, Bhatt DL, Eikelboom JW, Konkle B, et al. Mean platelet volume as a predictor of cardiovascular risk: a systematic review and meta-analysis. J. Thrombosis Haemostasis : JTH. (2010) 8(1):148-56. Epub 2009/08/19. doi: 10.1111/j.1538-7836.2009.03584.x
https://doi.org/10.1111/j.1538-7836.2009.03584.x
Scharbert G, Kalb M, Marschalek C, Kozek-Langenecker SA. The effects of test temperature and storage temperature on platelet aggregation: a whole blood in vitro study. Anesthesia & Analgesia. (2006) 102(4):1280-4. doi: 10.1213/01.ane.0000199399.04496.6d
https://doi.org/10.1213/01.ane.0000199399.04496.6d
Hedberg P, Lehto T. Aging stability of complete blood count and white blood cell differential parameters analyzed by Abbott CELL-DYN Sapphire hematology analyzer. Int. J. Lab. Hemat. (2009) 31(1):87-96. doi: 10.1111/j.1751-553X.2007.01009.x
https://doi.org/10.1111/j.1751-553X.2007.01009.x
Gunawardena D, Jayaweera S, Madhubhashini G, Lokumarakkala DD, Senanayake SJ. Reliability of Parameters of Complete Blood Count With Different Storage Conditions. J. Clin. Lab. Analysis. (2017) 31(2):e22042. doi: 10.1002/jcla.22042
https://doi.org/10.1002/jcla.22042
de Baca ME, Gulati G, Kocher W, Schwarting R. Effects of Storage of Blood at Room Temperature on Hematologic Parameters Measured on Sysmex XE-2100. Lab. Med. (2006) 37(1):28-36. https://doi.org/10.1309/1EERK1M02QFJRX6P
https://doi.org/10.1309/1EERK1M02QFJRX6P
Cornet E, Behier C, Troussard X. Guidance for storing blood samples in laboratories performing complete blood count with differential. Int. J. Lab. Hem. (2012) 34(6):655-60. doi: 10.1111/j.1751-553X.2012.01452.x
https://doi.org/10.1111/j.1751-553X.2012.01452.x
Mahmoodi M, Hajizadeh M, Rashidinejad H, Asadikaram G, Khaksari M, Mirzaee M, et al. Survey of changes in complete blood count and red cell indices of whole blood incubated in vitro at different temperatures up to 48 hours. J Ayub Med Coll Abbottabad. (2006) 18(1):14-6. https://pubmed.ncbi.nlm.nih.gov/16773962/
Jain A, Jain S, Singh N, Aswal P, Pal S, Meinia SK, et al. Storage stability of commonly used haematological parameters at 33 °C: Electronic supplementary material available online for this article. Biochemia Medica. (2018) 28(2):020901-. Epub 2018/04/15. doi: 10.11613/BM.2018.020901
https://doi.org/10.11613/BM.2018.020901
Wu D-W, Li Y-M, Wang F. How Long can we Store Blood Samples: A Systematic Review and Meta-Analysis. EBioMedicine. (2017) 24: 277-85. doi: 10.1016/j.ebiom.2017.09.024
https://doi.org/10.1016/j.ebiom.2017.09.024
Egidi MG, D'Alessandro A, Mandarello G, Zolla L. Troubleshooting in platelet storage temperature and new perspectives through proteomics. Blood transfusion = Trasfusione del sangue. (2010) 8 (3):73-81. doi: 10.2450/2010.012S
Pintér E, László K, Schüszler I, Konderák J. The stability of quantitative blood count parameters using the ADVIA 2120i hematology analyzer. Practical Lab. Med. (2016) 4:16-21. doi: 10.1016/j.plabm.2015.12.001
https://doi.org/10.1016/j.plabm.2015.12.001
Singh H, Chaudhary R, Ray V. Evaluation of platelet storage lesions in platelet concentrates stored for seven days. (2003). https://pubmed.ncbi.nlm.nih.gov/14870797/
Imeri F, Herklotz R, Risch L, Arbetsleitner C, Zerlauth M, Risch GM, et al. Stability of hematological analytes depends on the hematology analyser used: A stability study with Bayer Advia 120, Beckman Coulter LH 750 and Sysmex XE 2100. Clinica Chimica Acta. (2008) 397(1):68-71. doi: 10.1016/j.cca.2008.07.018
https://doi.org/10.1016/j.cca.2008.07.018
Daves M, Zagler EM, Cemin R, Gnech F, Joos A, Platzgummer S, et al. Sample stability for complete blood cell count using the Sysmex XN haematological analyser. Blood transfusion = Trasfusione del sangue. (2015) 13(4):576-82. doi: 10.2450/2015.0007-15
Chandrashekar V. Plateletcrit as a Screening Tool for Detection of Platelet Quantitative Disorders. (2013). doi:10.4021/jh70w
Zini G. Stability of complete blood count parameters with storage: toward defined specifications for different diagnostic applications. Int. J. Lab. Hem. (2014) 36(2):111-3. doi: 10.1111/ijlh.12181
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2021 Pakistan BioMedical Journal
This work is licensed under a Creative Commons Attribution 4.0 International License.
This is an open-access journal and all the published articles / items are distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. For comments editor@pakistanbmj.com