Diagnostic Accuracy of Contrast-Enhanced FLAIR MRI in the Diagnosis of Meningitis, Keeping CSF Analysis as the Gold Standard

Contrast-Enhanced FLAIR MRI in Meningitis, Keeping CSF as the Gold Standard

Authors

  • Aymen Shahab Department of Radiology, Shahab General Hospital, Peshawar, Pakistan
  • Faria Maqsood Department of Radiology, Hayatabad Medical Complex, Peshawar, Pakistan
  • Mehreen Khan Department of Radiology, Hayatabad Medical Complex, Peshawar, Pakistan
  • Ayesha Waheed Department of Radiology, Hayatabad Medical Complex, Peshawar, Pakistan
  • Nayab Motasim Department of Radiology, Hayatabad Medical Complex, Peshawar, Pakistan
  • Shanza Ijaz Department of Radiology, Hayatabad Medical Complex, Peshawar, Pakistan

DOI:

https://doi.org/10.54393/pbmj.v9i9.1422

Keywords:

Meningitis, CE-FLAIR MRI, Cerebrospinal Fluid, Diagnostic Accuracy, Sensitivity, Specificity

Abstract

Meningitis is a potentially life-threatening inflammation of the meninges that requires prompt diagnosis to reduce neurological complications and mortality. Cerebrospinal fluid (CSF) analysis remains the reference standard, but contrast-enhanced fluid-attenuated inversion recovery magnetic resonance imaging (CE-FLAIR MRI) may improve detection of meningeal enhancement and complement CSF assessment. Objective: To determine the diagnostic accuracy of CE-FLAIR MRI for meningitis using CSF analysis as the reference standard. Methods: This cross-sectional diagnostic accuracy study included 103 patients with suspected meningitis at MTI/Hayatabad Medical Complex, Peshawar, from May to November 2022. All participants underwent CE-FLAIR MRI and CSF analysis. Diagnostic performance was assessed using a 2 × 2 contingency table, and sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and overall accuracy were calculated with 95% confidence intervals. Results: Among 103 patients, 61 were CSF-positive, and 42 were CSF-negative. CE-FLAIR MRI identified 55 true-positive, 34 true-negative, 8 false-positive, and 6 false-negative cases. Sensitivity was 90.2% (95% CI: 80.2–95.4), specificity 81.0% (66.7–90.0), PPV 87.3% (76.9–93.4), NPV 85.0% (70.9–92.9), and overall accuracy 86.4% (78.5–91.7). CE-FLAIR MRI showed a strong association with CSF-confirmed meningitis (Cramer’s V = 0.717, p<0.001). Conclusions: CE-FLAIR MRI showed good diagnostic performance and may serve as a useful non-invasive adjunct to CSF analysis in suspected meningitis; however, it should not replace CSF assessment where lumbar puncture is feasible.

Views: 406Downloads: 107

Author Biographies

  • Ayesha Waheed, Department of Radiology, Hayatabad Medical Complex, Peshawar, Pakistan
     

     

       
  • Nayab Motasim, Department of Radiology, Hayatabad Medical Complex, Peshawar, Pakistan
     
           

References

Kamr WH, Eissawy MG, Saadawy A. The Value of Contrast-Enhanced FLAIR Magnetic Resonance Imaging in Detecting Meningeal Abnormalities in Suspected Cases of Meningitis Compared to Conventional Contrast-Enhanced T1WI Sequences. Egyptian Journal of Radiology and Nuclear Medicine. 2020 Nov; 51(1): 231. doi: 10.1186/s43055-020-00348-2. DOI: https://doi.org/10.1186/s43055-020-00348-2

Ahn SJ, Taoka T, Moon WJ, Naganawa S. Contrast‐Enhanced Fluid‐Attenuated Inversion Recovery in Neuroimaging: A Narrative Review on Clinical Applications and Technical Advances. Journal of Magnetic Resonance Imaging. 2022 Aug; 56(2): 341-53. doi: 10.1002/jmri.28117. DOI: https://doi.org/10.1002/jmri.28117

Akram A, Chaudhry S, Arbab S. Diagnostic Accuracy of MRI Contrast Enhanced FLAIR and T1-Weighted Images in Diagnosis of Infectious Meningitis Taking CSF Analysis as Reference Standard. Infectious Diseases Journal of Pakistan. 2026 Jun; 35(2): 162-7. doi: 10.61529/idjp.v35i2.535. DOI: https://doi.org/10.61529/idjp.v35i2.535

Gad M, Elsorogy LG, Moustafa SA. Diagnostic Utility of Contrast-Enhanced FLAIR MRI in Imaging of Demyelinating and Infectious Brain Lesions. Egyptian Journal of Radiology and Nuclear Medicine. 2023 Jun; 54(1): 104. doi: 10.1186/s43055-023-01049-2. DOI: https://doi.org/10.1186/s43055-023-01049-2

Aygun B, Biswas A, Blaaza M, Cooper J, Gaur P, Avsenik J et al. Improved Diagnostic Accuracy for Leptomeningeal Dissemination in Pediatric Brain Tumors Using Contrast-Enhanced FLAIR Imaging. Neuro-Oncology Practice. 2025 Feb; 12(1): 51-7. doi: 10.1093/nop/npae075. DOI: https://doi.org/10.1093/nop/npae075

Khalid MS, Arooj S, Asghar A, Mansoor A, Masood M, Afzal F et al. Diagnostic Accuracy of Contrast Enhanced T2 Flair in Diagnosing Infective Meningitis Considering CSF Analysis as Gold Standard. Pakistan Postgraduate Medical Journal. 2023 Sep; 34(03): 125-30. doi: 10.51642/ppmj.v34i03.606. DOI: https://doi.org/10.51642/ppmj.v34i03.606

Kirar RS, Uniyal R, Garg RK, Verma R, Malhotra HS, Sharma PK et al. Occurrence and Determinants of Seizures and Their Impact on Tuberculous Meningitis: A Prospective Evaluation. Acta Neurologica Belgica. 2024 Jun; 124(3): 821-9. doi: 10.1007/s13760-023-02444-2. DOI: https://doi.org/10.1007/s13760-023-02444-2

Buderer NM. Statistical Methodology: I. Incorporating the Prevalence of Disease into the Sample Size Calculation for Sensitivity and Specificity. Academic Emergency Medicine. 1996 Sep; 3(9): 895-900. doi: 10.1111/j.1553-2712.1996.tb03538.x. DOI: https://doi.org/10.1111/j.1553-2712.1996.tb03538.x

Shahan B, Choi EY, Nieves G. Cerebrospinal Fluid Analysis. American Family Physician. 2021 Apr; 103(7): 422-8.

Sanjay P, Manohar V, Balol S, Yashwanth Naik MB. Diagnostic Performance of Contrast-Enhanced T2-FLAIR MRI in the Detection of Meningitis. SA Journal of Radiology. 2025; 29(1): 1-9. doi: 10.4102/sajr.v29i1.3018. DOI: https://doi.org/10.4102/sajr.v29i1.3018

Mushtaq R, Arooj S, Kalsoom U, Raja R. Role of Contrast Enhanced FLAIR MRI as a New Tool in Diagnosing Tuberculous Meningitis. Pakistan Armed Forces Medical Journal. 2020 Oct; 31(5): 1310.

Mishra S, Naik S, Bhoi SK, Kumar M, Deep N, Dey A et al. Comparison of Post Contrast Fluid Attenuated Inversion Recovery, 3D T1-SPACE, and T1W MRI Sequences with Fat Suppression in the Diagnosis of Infectious Meningitis. The Neuroradiology Journal. 2023 Oct; 36(5): 572-80. doi: 10.1177/19714009231163563. DOI: https://doi.org/10.1177/19714009231163563

Freeze WM, van der Thiel M, de Bresser J, Klijn CJ, van Etten ES, Jansen JF et al. CSF Enhancement on Post-Contrast Fluid-Attenuated Inversion Recovery Images; A Systematic Review. NeuroImage: Clinical. 2020 Jan; 28: 102456. doi: 10.1016/j.nicl.2020.102456. DOI: https://doi.org/10.1016/j.nicl.2020.102456

Kumar S, Singh P, Vyas S, Modi M, Agarwal V, Goyal MK, Sankhyan N. Assessment of Blood–Brain Barrier Integrity in Tuberculous Meningitis Using Dynamic Contrast-Enhanced MR Perfusion. Indian Journal of Radiology and Imaging. 2021 Jan; 31(01): 030-6.

Ma Q, Yi Y, Liu T, Wen X, Shan F, Feng F et al. MRI-Based Radiomics Signature for Identification of Invisible Basal Cisterns Changes in Tuberculous Meningitis: A Preliminary Multicenter Study. European Radiology. 2022 Dec; 32(12): 8659-69. doi: 10.1007/s00330-022-08911-3. DOI: https://doi.org/10.1007/s00330-022-08911-3

Goto R, Horiuchi Y, Kawakami H, Chikada A, Yasuda T, Takeuchi S et al. Cerebrospinal Fluid Analysis Is Associated with Enhancement on MRI in Bacterial and Tuberculous Meningitis: A Retrospective Observational Study. Clinical Neurology and Neurosurgery. 2022 Jan; 212: 107036. doi: 10.1016/j.clineuro.2021.107036. DOI: https://doi.org/10.1016/j.clineuro.2021.107036

Long Y, Peng Y, Huang Z, Zhu M, Wan C. Enhancing the Cytological Features and Diagnostic Significance of Cerebrospinal Fluid in Bacterial Meningitis. CytoJournal. 2024 Jul; 21: 24. doi: 10.25259/Cytojournal_111_2023. DOI: https://doi.org/10.25259/Cytojournal_111_2023

Parihar R, Shukla R, Baishya B, Kalita J, Haldar R, Misra UK. NMR Based CSF Metabolomics in Tuberculous Meningitis: Correlation with Clinical and MRI Findings. Metabolic Brain Disease. 2022 Mar; 37(3): 773-85. doi: 10.1007/s11011-021-00860-y. DOI: https://doi.org/10.1007/s11011-021-00860-y

Chen W, Liu G, Cui L, Tian F, Zhang J, Zhao J et al. Evaluation of Metagenomic and Pathogen-Targeted Next-Generation Sequencing for Diagnosis of Meningitis and Encephalitis in Adults: A Multicenter Prospective Observational Cohort Study in China. Journal of Infection. 2024 May; 88(5): 106143. doi: 10.1016/j.jinf.2024.106143. DOI: https://doi.org/10.1016/j.jinf.2024.106143

Dian S, Hermawan R, van Laarhoven A, Immaculata S, Achmad TH, Ruslami R et al. Brain MRI Findings in Relation to Clinical Characteristics and Outcome of Tuberculous Meningitis. PLOS ONE. 2020 Nov; 15(11): e0241974. doi: 10.1371/journal.pone.0241974. DOI: https://doi.org/10.1371/journal.pone.0241974

Choudhary N, Vyas S, Modi M, Raj S, Kumar A, Sankhyan N et al. MR Vessel Wall Imaging in Tubercular Meningitis. Neuroradiology. 2021 Oct; 63(10): 1627-34. doi: 10.1007/s00234-021-02678-y. DOI: https://doi.org/10.1007/s00234-021-02678-y

Shabbir S and Sheikh M. Positive Predictive Value of Contrast-Enhanced Fluid-Attenuated Inversion Recovery (FLAIR) Magnetic Resonance Imaging in Diagnosis of Meningitis Among Pediatrics Taking Cerebrospinal Fluid Analysis as Gold Standard. Cureus. 2024 Nov; 16(11). doi: 10.7759/cureus.73356. DOI: https://doi.org/10.7759/cureus.73356

Downloads

Check for updates

Published

2026-09-30

Issue

Section

Original Article

How to Cite

Shahab, A., Maqsood, F., Khan, M., Waheed, A., Motasim, N., & Ijaz, S. (2026). Diagnostic Accuracy of Contrast-Enhanced FLAIR MRI in the Diagnosis of Meningitis, Keeping CSF Analysis as the Gold Standard: Contrast-Enhanced FLAIR MRI in Meningitis, Keeping CSF as the Gold Standard. Pakistan BioMedical Journal, 9(9), 03-09. https://doi.org/10.54393/pbmj.v9i9.1422

Plaudit

Similar Articles

11-20 of 486

You may also start an advanced similarity search for this article.